1.6 REGULATING RANSFORMERS


Type

Rated capacity, kVA Rated winding voltage, kV Type, range and
number of

voltage
regulation
steps
Winding
scheme and
connection
group
Cooling
HV MV LV


ТДТН-10000/110-У1


10000


115

16,5; 22,0


6,6; 11,0

OLTC in neutral of
HV ± 16%, ± 9 steps;
NLTC on MV side
34,5 и 38,5 кВ
± (2х2,5%)
Ynd11d11 ONAF
34,5; 38,5 YNyn0d11


ТДТН-16000/110-У1


16000


115

22,0


6,6; 11,0

Ynd11d11
34,5; 38,5 YNyn0d11


ТДТН-25000/110-У1


25000


115

11,0 6,6 OLTC in neutral of
HV ± 16%, ± 9 steps
Ynd11d11
22,0 6,6; 11,0
34,5; 38,5 6,3;6,6; 11,0 YNyn0d11
ТДТНЖ-25000/110-У1 25000 115 27,5 6,6; 11,0 Ynd11d11


ТДТН-25000/110-У1(ХЛ1)


25000


115

11,0 6,6 OLTC in neutral of
HV ± 16%, ± 9 steps;
NLTC on MV side
34,5; 38,5 ; 36 кВ
± (2х2,5%)


Ynd11d11

22,0 6,6; 11,0
34,5; 38,5 6,3; 6,6; 11,0 YNyn0d11
ТДТН-25000/110-ХЛ1 25000 115 38,5 6,6


ТДТН-40000/110-У1


40000


115

10,5 6,3


Ynd11d11

11,0 6,6
22,0 6,6; 11,0
34,5; 38,5 6,6; 11,0 YNyn0d11
36 10,5 Yy0d11
ТДТНЖ-40000/110-У1 40000 115 27,5 6,6; 11,0 OLTC in neutral of
HV ± 16%, ± 9 steps
Ynd11d11


ТДТН-63000/110-У1


63000


115

11,0 6,6 OLTC in neutral of
HV ± 16%, ± 9 steps;
NLTC on MV side
34,5 и 38,5 кВ
± (2х2,5%)
Ynd11d11
38,5 6,6; 11,0 YNyn0d11
ТДЦТН-63000/110-У1 63000 115 34,5 6,6; 11,0 YNyn0d11 OFAF
ТДТН-80000/110-У1 80000 115 38,5 6,6; 11,0 YNyn0d11 ONAF


ТДЦТН-80000/110-У1


80000


115

11,0 6,6; 6,94 OLTC in neutral of
HV ± 16%, ± 9 steps
Ynd11d11


OFAF

22,0; 38,5 11,0 YNyn0d11


ТДЦТН-100000/220-У1

100000/

70000/

30000


230


22,0


10,5

OLTC in neutral of
HV ± 10% (± 10
steps)


YNyn0d11

ONAN / ONAF/
OFAF

100000/

83000/

100000


230


22,0


11,0

OLTC in neutral of
HV ± 8 х 1,5%;
NLTC on MV side ±
2х2,5%


OFAF

ТДЦТН-125000/220-У1

125000/

83000/

125000


230


22,0


11,0